PUBLIC WATER SYSTEM IMPROVEMENTS DIVISION II WATER TREATMENT PLANT AND WELLHOUSE IMPROVE FOR THE TOWN OF AKRON FULTON COUNTY, INDIANA MARCH 2025 NOT TO SCALE PROJECT LOCATION TOWN COUNCIL JIM SANER, PRESIDENT RICH SOLANO, VICE PRESIDENT TONY RAMERIZ, MEMBER CLERK-TREASURER REBECCA HARTZLER ATTORNEY T. ANDREW PERKINS PERKINS & ADLEY ROCHESTER, IN SUPERINTENDENT JAKE GEARHART Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern GENERAL LOCATION MAP Author: DPATTERSON, Plot Date: 4/2/2025 7:59 AM Path: Z:\CAD_INCOMPLETE\2024094-00_AKRON_PUBLIC WATER SYSTEM IMPROVEMENTS\025_PRODUCTIONDWG\DIVISION II\01 TITLE SHEET.DWG 1 BID SET STATE OF No. PE920059 MARK M. SULLIVAN PROFESSIONAL ENGINEER REGISTERED INDIANA
P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street 20 Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern BID SET Author: DPATTERSON, Plot Date: 4/2/2025 7:58 AM Path: Z:\CAD_INCOMPLETE\2024094-00_AKRON_PUBLIC WATER SYSTEM IMPROVEMENTS\025_PRODUCTIONDWG\DIVISION II\02 INFO SHEET.DWG WASTEWATER TREATMENT PLANT FACILITY PHOSPHORUS REMOVAL IMPROVEMENTS FOR THE CITY OF PLYMOUTH, MARSHALL COUNTY, INDIANA STATE OF No. PE60920059 MARK M. SULLIVAN PROFESSIONAL ENGINEER REGISTERED INDIANA GENERAL INFO SHEET 6" TOWN OF AKRON Know what's below. before you dig. Call R STREET DEPARTMENT: LEGEND POLICE DEPARTMENT PIPELINE: ELECTRIC: S MISHAWAKA ST IN-19 W ROCHESTER ST 0 200 400 SCALE: 1" = 400' IN-14 UTILITIES CABLE TV: COMMUNICATIONS: GAS: SEWER, STORM, WATER: TELEPHONE: DIVISION II - WATER TREATMENT PLANT FILTER MEDIA REPLACEMENT DIVISION II - WELLHOUSE #1 IMPROVEMENTS DIVISION II - WELLHOUSE #2 IMPROVEMENTS DIVISION I - WATER MAIN REPLACEMENT 25 2 SHEET SCHEDULE PG. TITLE 1 COVER SHEET 2 GENERAL INFO SHEET 3 RAW WATER PRODUCTION WELL I AND WELL II IMPROVEMENTS 4 WATER TREATMENT UNIT IMPROVEMENTS - PLAN, SECTION AND MEDIA DETA 5 PROPOSED ELECTRICAL SITE PLAN DIVISION III - NORTH TANK IMPROVEMENTS DIVISION III - SOUTH TANK IMPROVEMENTS AREA MAP N
P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street 20 Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern BID SET Author: DPATTERSON, Plot Date: 4/2/2025 7:54 AM Path: Z:\CAD_INCOMPLETE\2024094-00_AKRON_PUBLIC WATER SYSTEM IMPROVEMENTS\025_PRODUCTIONDWG\DIVISION II\03 EAST_WEST WELLHOUSEIMPS.DWG WASTEWATER TREATMENT PLANT FACILITY PHOSPHORUS REMOVAL IMPROVEMENTS FOR THE CITY OF PLYMOUTH, MARSHALL COUNTY, INDIANA GENERAL NOTES : 1. CONTRACTOR TO REMOVE BUILDING ROOF AND REMOVE EXISTING WELL PUMP. 2. CONTRACTOR TO CLEAN AND REDEVELOP EXISTING WELL. 3. CONTRACTOR TO REINSTALL WELL PUMP AND REPLACE ROOF STRUCTURE. 4. NEW AIR RELEASE VALVE DRAIN LINE TO BE CONNECTED TO EXISTING DRAIN LINE. 5. RECONNECT ALL TUBES AND PIPING ASSOCIATED WITH PUMP OPERATION. 6. THE PROPOSED PIPE AND FITTING LAYOUT SHALL MATCH THE EXISTING LAYOUT. USE OF 6" SPOOL PIECES SHALL BE USED TO SPACE OUT THE REMOVAL OF THE EXISTING FLOW METERS. LEGEND EXISTING ITEM TO BE REMOVED WELLHOUSE I PIPING DEMOLITION DETAIL SEE GENERAL NOTE 2 SEE GENERAL NOTE 1 FILTER TANK EQUIPMENT KEY NUMBER PIPING SCHEDULE 1 Existing Pump Motor to be Pulled 2 Existing Discharge Head to be Pulled 3 Existing Pressure Gauge and Tubing to be Replaced as needed 4 Existing 6" x 2" DI ARV Tap to be Removed 5 Existing 11 2" x 1 2" Threaded Sample Tap to be Removed 6 Existing 11 2" Isolation Valve to be Removed 7 Existing ARV to be Removed 8 Existing 1" ARV DI Drain w/ Backflow Prevention Valve to be Removed 9 Existing 6" Flow Meter to be Removed 10 Existing 6" Check Valve to be Removed 11 Existing 6" Gate Valve to be Removed 12 Existing 6" DI Spool Piece to be Removed 13 Existing 6" DI Tee w/ Blind Flange to be Removed 14 Existing Pipe Stanchion to be Removed 15 Existing 6" DI Discharge Floor Pipe to Remain in Use. 16 Proposed 6" x 4" DI Tee w/ Threaded 11 2" Tap for New ARV Connection 17 Proposed 2" x 1 2" Sample Tap w/ Isolation Valve 18 Proposed 2" Isolation Valve and Threaded Pipe to New ARV 19 Proposed 2" ARV w/ 1" Drain Line and New Backflow Prevention Device 20 Proposed 6" DI Pipe 21 Proposed 6" Flowmeter 22 Proposed Check Valve 23 Proposed 6" Gate Valve 24 Proposed 6" DI 90° Bend 25 Provide Adjustable Pipe Support Stanchion as Needed. 26 Proposed ARV Drain line to Connect to Existing w/ Threaded Companion Flange 1 2 3 3 4 8 SEE GENERAL NOTE 1 1 2 3 3 4 SEE GENERAL NOTE 2 5 6 9 7 8 14 10 11 12 13 15 7 9 10 11 13 14 15 3 3 SEE GENERAL NOTE 3 19 17 16 23 22 21 20 18 24 25 SEE GENERAL NOTE 3 15 15 3 16 17 18 19 19 SEE GENERAL NOTE 4 SEE GENERAL NOTE 4 23 24 21 22 20 25 SEE GENERAL NOTE 5 EXISTING CONCRETE BASE (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) EXISTING CONCRETE BASE EXISTING CONCRETE BASE SEE GENERAL NOTE 3 (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) (EXISTING WALL) WELLHOUSE I PIPING IMPROVEMENTS - PLAN VIEW 3 3 19 16 20 23 22 21 24 26 1 3 1 3 PIPING IMPROVEMENTS SECTION VIEW 1 WELLHOUSE I I PIPING DEMOLITION DETAIL 3 (EXISTING WALL) 26 SEE GENERAL NOTE 5 SEE GENERAL NOTE 3 SEE GENERAL NOTE 3 SEE GENERAL NOTE 3 SEE GENERAL NOTE 3 WELLHOUSE I I PIPING IMPROVEMENTS - PLAN VIEW PIPING IMPROVEMENTS SECTION VIEW 2 2 3 2 3 ALUMINUM CONDUIT ALUMINUM CONDUIT 24 23 22 21 16 20 19 (EXISTING WALL) EXISTING CONCRETE BASE EXISTING CONCRETE BASE ALUMINUM CONDUIT EXISTING CONCRETE BASE 1 14 RAW WATER PRODUCTION WELL I AND WELL II IMPROVEMENTS 25 3 STATE OF No. PE60920059 MARK M. SULLIVAN PROFESSIONAL ENGINEER REGISTERED INDIANA
P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street 20 Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern BID SET Author: DPATTERSON, Plot Date: 4/2/2025 7:53 AM Path: Z:\CAD_INCOMPLETE\2024094-00_AKRON_PUBLIC WATER SYSTEM IMPROVEMENTS\025_PRODUCTIONDWG\DIVISION II\03 EAST_WEST WELLHOUSEIMPS.DWG WASTEWATER TREATMENT PLANT FACILITY PHOSPHORUS REMOVAL IMPROVEMENTS FOR THE CITY OF PLYMOUTH, MARSHALL COUNTY, INDIANA WATER TREATMENT TANK - PLAN VIEW FILTER TANK EQUIPMENT KEY NUMBER PIPING SCHEDULE 1 2" NPT CLRG for Air Wash Inlet to be Removed 2 3 4" Sch - 80 PVC Lateral, Typical, to be Removed (All Chambers) 3 2" CPLG for Air Wash to be Removed (4 Required) 4 2" Sch - 80 PVC Distribution Pipe, Pipe Caps, Union, Pipe Supports etc. to be Removed 5 2" C.I. Air Supply Pipe to be Removed 6 Air Blower and Cover to be Removed, Electrical supply to be Removed 7 6" Filter Influent Pipe (Out of Section) 8 6" Filter Effluent / Backwash Influent Pipe 9 Patch Filter Equipment Tank 10 6" x 4" x 6" Tee 11 4", 6" Butterfly Valve, Typical 12 6" Backwash Influent / Filtered Effluent 5 5 5 5 5 4 4 4 4 2 2 1 3 8 3 3 1 BACKWASH FILTER FACE PIPING 10 11 (Sump) 1 * 9 9 9 9 EXISTING FILTER EQUIPMENT 1 1 EXISTING RAW WATER INFLUENT FILTER TANK OVERFLOW PIPE 10 LEGEND EXISTING ITEM TO BE REMOVED 8 6 Water Treatment Tank - Profile View 1 (Sump) 10 BACKWASH DISCHARGE 1 4 2 9 5 5 7 3 8 EXISTING CMU WALL DETENTION TANK EFFLUENT FILTER FACE PIPING 6" INFLUENT HEADER EXISTING FILTER EQUIPMENT DETENTION TANK FLOOR EXISTING MANWAY EXISTING MANWAY COLLECTION PLATE EXISTING RAW WATER INFLUENT FILTER TANK OVERFLOW PIPE FIN. FLR. FIN. FLR. 6 EXISTING CMU WALL EXISTING FILTER MEDIA REPLACEMENT DETAIL FILTER TANK MEDIA KEY NUMBER MEDIA REPLACEMENT SCHEDULE 1 Existing Steel Detention Tank Floor 2 Existing Collector Plate 3 12" of Anthracite Cap 0.6mm - 0.8mm w/A Uniformity Coefficient Less Than 1.85 4 18" of Silica Sand, 0.43mm - 0.53mm w/A Uniformity Coefficient Less Than 1.65 5 4" of Torpedo Sand, 0.8mm - 1.2mm 6 4" of 1 4" x 1 8" Quartz 7 4" of 1 2" x 1 4" Quartz 8 4" of 3 4" x 1 2" Quartz 9 Existing Underdrain Plate 1 2 3 5 6 8 9 EXISTING FILTER EQUIPMENT DETENTION TANK FLOOR CONCRETE EQUIPMENT PAD EXISTING MANWAY, TYP. NOTES: 1. CONTRACTOR TO REMOVE EXISTING FILTER MEDIA; DISPOSE OF MEDIA IN A LEGAL MANOR. 2. CONTRACTOR TO VISUALLY INSPECT INTERIOR OF TREATMENT VESSEL; REPORT FINDINGS TO ENGINEER AND OWNER. 3. REPLACE MEDIA AS DESCRIBED BELOW AND IN ACCORDANCE WITH MEDIA TREATMENT RECOMMENDATIONS 4 7 N.T.S. WATER TREATMENT UNIT IMPROVEMENTS - PLAN, SECTION AND MEDIA DETA 25 4 STATE OF No. PE60920059 MARK M. SULLIVAN PROFESSIONAL ENGINEER REGISTERED INDIANA
GENERAL ELECTRICAL NOTES E E E E E E E E E E E E E E E E E E E E E E E E E WELL #1, WELL #2 AND WTP SCADA SYSTEM IMPROVEMENTS INSTALLATION BUBBLE NOTES PULL BOX SCHEDULE PROPOSED ELECTRICAL SITE PLAN 5 44610 P.O. Box 295 Loogootee, Indiana 47553 Midwestern Engineers, Inc. 802 West Broadway Street Quality Engineering Services Since 1959 802 West Broadway St., P.O. Box 295 Loogootee, IN 47553 Ph: 812-295-2800 6809 Corporate Drive, Indianapolis, IN 46278 Ph: 317-334-0262 Website: midwesterneng.com Email: meinc@midwesterneng.com Fax: 812-295-2801 Consultants Civil Mechanical Electrical Inc. Engineers, Midwestern 2025 BID SET Author: DPATTERSON, Plot Date: 4/2/2025 7:51 AM Path: Z:\CAD_INCOMPLETE\2024094-00_AKRON_PUBLIC WATER SYSTEM IMPROVEMENTS\025_PRODUCTIONDWG\DIVISION II\05 ELECTRICAL.DWG STATE OF No. PE11100002 ALAN F. BURCH PROFESSIONAL ENGINEER REGISTERED INDIANA PUBLIC WATER SYSTEM IMPROVEMENTS DIVISION II WATER TREATMENT PLANT AND WELLHOUSE IMPROVEMENTS FOR THE TOWN OF AKRON FULTON COUNTY, INDIANA N. VIRGIL ST. EXISTING WATER TREATMENT PLANT WELLHOUSE PIPING SECTION